Loading the content... Loading depends on your connection speed!

Allowable Batten Loads

Select the spacing of your lift lines to determine your batten capacity.

1" Sch. 40 Pipe
Uniform Strength: 27 lbs/ft
Uniform Deflection: 20 lbs/ft
Point Strength: 93 lbs
Point Deflection: 56 lbs
1¼" Sch. 40 Pipe
Uniform Strength: 48 lbs/ft
Uniform Deflection: 45 lbs/ft
Point Strength: 160 lbs
Point Deflection: 124 lbs
1¼" Sch. 80 Pipe
Uniform Strength: 61 lbs/ft
Uniform Deflection: 56 lbs/ft
Point Strength: 206 lbs
Point Deflection: 155 lbs
1½" Sch. 40 Pipe
Uniform Strength: 66 lbs/ft
Uniform Deflection: 72 lbs/ft
Point Strength: 221 lbs
Point Deflection: 197 lbs
1½" Sch. 80 Pipe
Uniform Strength: 86 lbs/ft
Uniform Deflection: 91 lbs/ft
Point Strength: 288 lbs
Point Deflection: 250 lbs
2" Sch. 40 Pipe
Uniform Strength: 113 lbs/ft
Uniform Deflection: 156 lbs/ft
Point Strength: 374 lbs
Point Deflection: 421 lbs
1" Sch. 40 Pipe
Uniform Strength: 21 lbs/ft
Uniform Deflection: 137 lbs/ft
Point Strength: 82 lbs
Point Deflection: 44 lbs
1¼" Sch. 40 Pipe
Uniform Strength: 37 lbs/ft
Uniform Deflection: 31 lbs/ft
Point Strength: 142 lbs
Point Deflection: 98 lbs
1¼" Sch. 80 Pipe
Uniform Strength: 48 lbs/ft
Uniform Deflection: 39 lbs/ft
Point Strength: 183 lbs
Point Deflection: 123 lbs
1½" Sch. 40 Pipe
Uniform Strength: 52 lbs/ft
Uniform Deflection: 50 llbs/ftbs
Point Strength: 196 lbs
Point Deflection: 155 lbs
1½" Sch. 80 Pipe
Uniform Strength: 67 lbs/ft
Uniform Deflection: 63 lbs/ft
Point Strength: 256 lbs
Point Deflection: 197 lbs
2" Sch. 40 Pipe
Uniform Strength: 89 lbs/ft
Uniform Deflection: 109 lbs/ft
Point Strength: 332 lbs
Point Deflection: 333 lbs
1" Sch. 40 Pipe
Uniform Strength: 17 lbs/ft
Uniform Deflection: 9 lbs/ft
Point Strength: 74 lbs
Point Deflection: 36 lbs
1¼" Sch. 40 Pipe
Uniform Strength: 30 lbs/ft
Uniform Deflection: 22 lbs/ft
Point Strength: 128 lbs
Point Deflection: 79 lbs
1¼" Sch. 80 Pipe
Uniform Strength: 38 lbs/ft
Uniform Deflection: 28 lbs/ft
Point Strength: 165 lbs
Point Deflection: 99 lbs
1½" Sch. 40 Pipe
Uniform Strength: 41 lbs/ft
Uniform Deflection: 36 lbs/ft
Point Strength: 176 lbs
Point Deflection: 126 lbs
1½" Sch. 80 Pipe
Uniform Strength: 54 lbs/ft
Uniform Deflection: 45 lbs/ft
Point Strength: 230 lbs
Point Deflection: 160 lbs
2" Sch. 40 Pipe
Uniform Strength: 71 lbs/ft
Uniform Deflection: 78 lbs/ft
Point Strength: 299 lbs
Point Deflection: 269 lbs
1" Sch. 40 Pipe
Uniform Strength: 14 lbs/ft
Uniform Deflection: 7 lbs/ft
Point Strength: 67 lbs
Point Deflection: 29 lbs
1¼" Sch. 40 Pipe
Uniform Strength: 24 lbs/ft
Uniform Deflection: 16 lbs/ft
Point Strength: 116 lbs
Point Deflection: 65 lbs
1¼" Sch. 80 Pipe
Uniform Strength: 31 lbs/ft
Uniform Deflection: 20 lbs/ft
Point Strength: 150 lbs
Point Deflection: 82 lbs
1½" Sch. 40 Pipe
Uniform Strength: 34 lbs/ft
Uniform Deflection: 26 lbs/ft
Point Strength: 160 lbs
Point Deflection: 104 lbs
1½" Sch. 80 Pipe
Uniform Strength: 44 lbs/ft
Uniform Deflection: 33 lbs/ft
Point Strength: 209 lbs
Point Deflection: 132 lbs
2" Sch. 40 Pipe
Uniform Strength: 58 lbs/ft
Uniform Deflection: 58 lbs/ft
Point Strength: 272 lbs
Point Deflection: 223 lbs
1" Sch. 40 Pipe
Uniform Strength: 11 lbs/ft
Uniform Deflection: 5 lbs/ft
Point Strength: 62 lbs
Point Deflection: 25 lbs
1¼" Sch. 40 Pipe
Uniform Strength: 20 lbs/ft
Uniform Deflection: 12 lbs/ft
Point Strength: 107 lbs
Point Deflection: 55 lbs
1¼" Sch. 80 Pipe
Uniform Strength: 26 lbs/ft
Uniform Deflection: 15 lbs/ft
Point Strength: 137 lbs
Point Deflection: 69 lbs
1½" Sch. 40 Pipe
Uniform Strength: 28 lbs/ft
Uniform Deflection: 20 lbs/ft
Point Strength: 147 lbs
Point Deflection: 87 lbs
1½" Sch. 80 Pipe
Uniform Strength: 36 lbs/ft
Uniform Deflection: 25 lbs/ft
Point Strength: 192 lbs
Point Deflection: 111 lbs
2" Sch. 40 Pipe
Uniform Strength: 48 lbs/ft
Uniform Deflection: 44 lbs/ft
Point Strength: 249 lbs
Point Deflection: 187 lbs
1" Sch. 40 Pipe
Uniform Strength: 9 lbs/ft
Uniform Deflection: 4 lbs/ft
Point Strength: 57 lbs
Point Deflection: 21 lbs
1¼" Sch. 40 Pipe
Uniform Strength: 17 lbs/ft
Uniform Deflection: 9 lbs/ft
Point Strength: 98 lbs
Point Deflection: 47 lbs
1¼" Sch. 80 Pipe
Uniform Strength: 21 lbs/ft
Uniform Deflection: 11 lbs/ft
Point Strength: 127 lbs
Point Deflection: 59 lbs
1½" Sch. 40 Pipe
Uniform Strength: 23 lbs/ft
Uniform Deflection: 15 lbs/ft
Point Strength: 136 lbs
Point Deflection: 74 lbs
1½" Sch. 80 Pipe
Uniform Strength: 30 lbs/ft
Uniform Deflection: 19 lbs/ft
Point Strength: 177 lbs
Point Deflection: 95 lbs
2" Sch. 40 Pipe
Uniform Strength: 41 lbs/ft
Uniform Deflection: 34 lbs/ft
Point Strength: 230 lbs
Point Deflection: 159 lbs
1" Sch. 40 Pipe
Uniform Strength: 8 lbs/ft
Uniform Deflection: 3 lbs/ft
Point Strength: 53 lbs
Point Deflection: 18 lbs
1¼" Sch. 40 Pipe
Uniform Strength: 14 lbs/ft
Uniform Deflection: 7 lbs/ft
Point Strength: 91 lbs
Point Deflection: 40 lbs
1¼" Sch. 80 Pipe
Uniform Strength: 18 lblbs/fts
Uniform Deflection: 9 lbs/ft
Point Strength: 118 lbs
Point Deflection: 51 lbs
1½" Sch. 40 Pipe
Uniform Strength: 20 lbs/ft
Uniform Deflection: 12 lbs/ft
Point Strength: 126 lbs
Point Deflection: 64 lbs
1½" Sch. 80 Pipe
Uniform Strength: 26 lbs/ft
Uniform Deflection: 15 lbs/ft
Point Strength: 164 lbs
Point Deflection: 82 lbs
2" Sch. 40 Pipe
Uniform Strength: 34 lbs/ft
Uniform Deflection: 27 lbs/ft
Point Strength: 213 lbs
Point Deflection: 137 lbs
1" Sch. 40 Pipe
Uniform Strength: 7 lbs/ft
Uniform Deflection: 2 lbs/ft
Point Strength: 49 lbs
Point Deflection: 16 lbs
1¼" Sch. 40 Pipe
Uniform Strength: 12 lbs/ft
Uniform Deflection: 5 lbs/ft
Point Strength: 85 lbs
Point Deflection: 35 lbs
1¼" Sch. 80 Pipe
Uniform Strength: 15 lbs/ft
Uniform Deflection: 6 lbs/ft
Point Strength: 110 lbs
Point Deflection: 44 lbs
1½" Sch. 40 Pipe
Uniform Strength: 17 lbs/ft
Uniform Deflection: 9 lbs/ft
Point Strength: 118 lbs
Point Deflection: 56 lbs
1½" Sch. 80 Pipe
Uniform Strength: 22 lbs/ft
Uniform Deflection: 11 lbs/ft
Point Strength: 153 lbs
Point Deflection: 71 lbs
2" Sch. 40 Pipe
Uniform Strength: 30 lbs/ft
Uniform Deflection: 21 lbs/ft
Point Strength: 199 lbs
Point Deflection: 120 lbs

1. All loads listed at the allowable static loads based on the requirements on ANSI E1.6-1 Powered Hoist Systems section 6.6.
2. Characteristic load assumed to be 125% of the static load.
3. Batten strength is limited so that the load imposed by the characteristic load does not exceed 75% of the allowable strength per AISC 360-05 (Specification for Steel Buildings - Allowable Stress Design).
4. Batten deflection is limited so that the calculated deflection due to the characteristic load not exceed L/180.
5. Battens assumed to be continuous over three spans.
6. Battens extend beyond last lift line by 3 feet or less.
7. ANSI E1.4 (Manual Counterweight Rigging Systems) requires battens to support 30 lbf/ft or 100 lb point load while limiting deflection to L/180. Spans highlighted in green meet this criteria.

Data is provided for general information on J.R. Clancy equipment which is in "as new" condition. Every effort has been made to make this data accurate. However, no guarantee of accuracy is made or implied.

Wenger and JR Clancy

Share Page

Close